Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Acta bioquím. clín. latinoam ; 42(2): 183-187, abr.-jun. 2008. tab
Artigo em Espanhol | LILACS | ID: lil-633046

RESUMO

En diciembre de 2005 se inició el Programa de Evaluación Externa de la Calidad (PEEC) para Laboratorios Andrológicos, organizado por la Facultad de Farmacia y Bioquimica, UBA y la Fundación Bioquímica Argentina. El objetivo del presente trabajo es informar la respuesta obtenida a la convocatoria de participar en el PEEC, dar a conocer los resultados de las primeras encuestas y compararlos con los relatados por otros programas extranjeros. Los parámetros evaluados fueron movilidad (video), morfología (fotografías digitales en CD) y recuento espermático (RE) (suspensiones de espermatozoides). Se solicitó utilizar la estandarización OMS 1999. Participaron 60 laboratorios. Los valores de Error de Medida Permitidos (EMP) fueron de 60%, 50%, 15% y 30% para morfología, movilidad progresiva rápida (MPR), movilidad progresiva (MP) y RE, respectivamente. Los resultados hallados fueron similares a los publicados por el Programa de Control de Calidad Externo del ASEBIR-España para el "nivel óptimo" de las especificaciones de calidad del "estado del arte". Cuando el requerimiento de calidad fue "variabilidad biológica", los EMP disminuyeron significativamente para morfología y MPR: 28,2% y 29,3% no así para MP y RE. La alta aceptación de la convocatoria pone de manifiesto la necesidad de un PEEC-Andrología. El elevado Error de Medida obtenido para morfología y movilidad progresiva rápida denota la necesidad de estandarizar los procedimientos y criterios para lograr el requerimiento de calidad de variabilidad biológica.


In December 2005 began the first External Quality Assessment Scheme (EQAS) for Andrology Laboratories organized by the School of Pharmacy and Biochemistry (University of Buenos Aires) and the Fundación Bioquímica Argentina. The aim of this study was to inform the response obtained after the enrollment to participate in the first Argentine EQAS, to discuss the results obtained in the first surveys and to compare them with the ones reported by other foreign programs. The evaluated parameters were sperm motility (videotapes), morphology (digital photography) and concentration (SC) (suspensions of spermatozoa). Participants were asked to follow WHO 1999. Nearly 60 laboratories throughout Argentine participated. The Total Allowable Error was 60%, 50%, 15% and 30% for morphology, progressive rapid motility (PRM), progressive motility (PM) and SC, respectively. The results found were similar to those published by the External Quality Program of the ASEBIR-Spain for the "optimum quality specification" on the "State of the art". When the established requirement of quality was "Biological Variability", the Total Allowable Error decreased significantly for morphology and PRM: 28.2% and 29.3% but not for PM and SC. The present data confirms the need for a Scheme. The high Total Error obtained for morphology and progressive rapid motility demamds to standardizing the procedures and establishing analytical goals based on Biological Variability.


Assuntos
Controle de Qualidade , Análise do Sêmen , Planos e Programas de Saúde/normas , Benchmarking , Variação Biológica da População , Diretrizes para o Planejamento em Saúde
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...